Pharmaceutical and biotech
-
Ascon TecnologicAscon Tecnologic continuous emission monitoring (CEMS) systems
Standard or custom CEMS systems with QAL1-certified analyzers, gas sampling and conditioning, and data acquisition and validation software.
-
Ascon TecnologicAscon Tecnologic temperature controllers
Ascon Tecnologic PID panel-mount temperature controllers: autotuning, thermocouple, Pt100 and universal signal inputs, alarms, retransmission and Modbus RTU.
-
KAYE (Amphenol)KAYE dry-block calibrators — LTR-90, LTR-150 and HTR-420
KAYE dry-block calibrators from −90 to 420 °C for automatic calibration of thermocouples and validation loggers, up to 48 sensors at once.
-
KAYE (Amphenol)Kaye LabWatch IoT — cloud environmental monitoring system (EMS) for GxP environments
Continuous monitoring, alarming and reporting in the AWS GxP cloud for warehouses, cleanrooms, laboratories and stability chambers, compliant with 21 CFR Part 11.
-
KAYE (Amphenol)Kaye Validator AVS — wired system for thermal validation and temperature mapping
Wired thermal validation system with up to 48 channels, a dedicated console and 21 CFR Part 11 compliance, for autoclaves, SIP, freeze dryers and stability chambers.
-
Ascon TecnologicAscon Tecnologic eCOMB: extractive combustion monitoring system
Extractive system for continuous measurement and recording of O₂, CO, CO₂ and flue gas temperature, with one panel for each emission point.
-
Ascon TecnologicAscon Tecnologic ZCO: in-situ NDIR CO analyzer
Cross-stack NDIR analyzer for carbon monoxide in flue gas, mounted directly on the stack, with no gas sampling and conditioning system.
-
KAYE (Amphenol)KAYE liquid calibration baths — CTR-25, CTR-40 and CTR-80
KAYE liquid calibration baths from −80 to 150 °C for simultaneous verification of several ValProbe data loggers and process sensors.
-
KAYE (Amphenol)Kaye ValProbe RT — wireless real-time thermal validation system
Wireless data loggers for temperature, pressure, humidity and CO₂, with real-time data over RF, for validating autoclaves, freeze dryers and stability chambers.
-
TE.MA.Pressure gauges for gauge and absolute pressure — TEMA
TEMA pressure gauges with Bourdon tube, diaphragm or capsule, for pressure, vacuum and compound ranges, from 0–4 mbar to 0–1600 bar; stainless steel cases, class up to 0.5, IP67, ATEX and PED.
-
TE.MA.Differential pressure gauges — TEMA MDB1200, MDC1200, MDM1200, MDP200
TEMA differential pressure gauges with diaphragm, double Bourdon tube, capsule or piston, from 0–4 mbar, for static pressures up to 400 bar; stainless steel cases, IP65, optional electrical contacts.
-
Ascon TecnologicAscon Tecnologic iCOMB: in-situ systems for combustion control
In-situ solutions for measuring O₂, CO and flue gas temperature directly on the stack, from individual analyzers to integrated systems with recording.
-
TE.MA.Diaphragm seals (pressure isolators) — TEMA SEP531 … SEP536/S
TEMA diaphragm seals for pressure gauges and transmitters: hygienic versions (DIN 11851, ISO 2852 clamp), flanged, threaded or sandwich type, up to 600 bar and −60 … +400 °C.
-
KAYE (Amphenol)Kaye IRTD-400 — high-accuracy temperature reference standard, −196 … 420 °C
Traceable reference probe with ±0.025 °C accuracy from −196 to 420 °C, the reference for automatic sensor calibration in Kaye validation systems.
-

Multifunction process calibrators — Additel ADT226 and Beamex MC6
Portable calibrators for temperature, pressure and electrical signals: Additel ADT226 / ADT226Ex (ATEX, IP67) and Beamex MC6 with HART, FF and Profibus PA communicator.
-
TE.MA.Bimetal and gas analog thermometers — TEMA TM800
Bimetal and gas-expansion analog thermometers, with rigid stem or capillary, for −200 … +700 °C. Representative model: TEMA TM800, all stainless steel.
-
TEGAM (Advanced Energy)TEGAM 911B / 912B — portable digital thermocouple thermometers
Portable digital thermometers with one (911B) or two inputs (912B) for K, J, T, E thermocouples. Accuracy ±(0.04 % of reading + 0.3 °C), 2000 hours of battery life.
-
RUEGERIndustrial thermocouples and RTDs — RUEGER S41-TC and S10-RTD
Pt100 RTDs and thermocouples for process use, in standard or Ex i / Ex d versions, with immersion lengths of 50 … 1000 mm. RUEGER S41-TC (up to 1800 °C) and S10-RTD models.
-
KAYE (Amphenol)Kaye HygroCal100 — portable relative humidity calibrator, 5–95 % RH
Portable humidity generator, 5–95 % RH, for automatic verification of up to 8 ValProbe RT humidity loggers or other RH sensors.
-
INORINOR temperature transmitters, 4–20 mA, NFC and HART
INOR temperature transmitters with 4–20 mA output for RTDs, thermocouples or universal input, with NFC configuration; HART, Ex and dual-channel versions.