TEGAM 911B / 912B — portable digital thermocouple thermometers
Portable digital thermometers with one (911B) or two inputs (912B) for K, J, T, E thermocouples. Accuracy ±(0.04 % of reading + 0.3 °C), 2000 hours of battery life.
| Inputs | 911B: 1 input; 912B: 2 inputs |
|---|---|
| Thermocouple types | K, J, T, E |
| Type K range | −200 … 1372 °C |
| Type J range | −210 … 1200 °C |
| Type T / type E range | −250 … 400 °C / −250 … 1000 °C |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
The TEGAM 911B and 912B are portable digital thermometers for measuring temperature with K, J, T and E type thermocouples, in the process, in the laboratory and in quality control. The Probe Offset function compensates for probe error, so that the accuracy of the probe–instrument system approaches that of the instrument itself. The 911B has a single input; the 912B has two inputs and also displays the T1−T2 difference.
Key benefits
- Basic accuracy ±(0.04 % of reading + 0.3 °C), with a recommended calibration cycle of 2 years.
- Real-time statistics: MIN, MAX, AVG, span, T1−T2 and standard deviation, with the statistics run time.
- 2000 hours of battery life on three ordinary AA alkaline batteries.
- Ergonomic, seamless, easy-to-clean housing for one-handed operation; survives 4 drops from 1 m onto concrete.
- Supplied with a traceability certificate; 3-year warranty.
Which model to choose
911B for single-point measurement: routine checks, maintenance, process control. 912B when two points must be monitored simultaneously, for example two components or two zones of the same process. The effective range depends on the thermocouple type and the probe used; probes are selected separately, according to the application.
Available models
- TEGAM 911B — Thermocouple thermometer, one input, for single-point measurement.
- TEGAM 912B — Thermocouple thermometer, two inputs, with T1−T2 difference display.
Applications
- Industrial process control
- Quality control and laboratory checks
- Materials testing and characterization
- Equipment maintenance
- Food and pharmaceutical industry
- Testing and validation
Technical specifications
| Inputs | 911B: 1 input; 912B: 2 inputs |
|---|---|
| Thermocouple types | K, J, T, E |
| Type K range | −200 … 1372 °C |
| Type J range | −210 … 1200 °C |
| Type T / type E range | −250 … 400 °C / −250 … 1000 °C |
| Basic accuracy | ±(0.04 % of reading + 0.3 °C) |
| Display resolution | 0.1° below 1000°, 1° above 1000°; 4 digits, backlit |
| Reading rate | 3 readings/s |
| Connector | Mini-TC |
| Power supply and battery life | 3 AA alkaline batteries; 2000 h |
| Operating environment | −20 … 55 °C; 5 … 95 % RH (10 … 30 °C); altitude 0 … 4600 m |
| Dimensions and weight | 193 × 84 × 28 mm; 300.9 g (911B), 303.2 g (912B), with batteries |
| Warranty | 3 years; calibration warranty 2 years |