Skip to content

Multifunction process calibrators — Additel ADT226 and Beamex MC6

Portable calibrators for temperature, pressure and electrical signals: Additel ADT226 / ADT226Ex (ATEX, IP67) and Beamex MC6 with HART, FF and Profibus PA communicator.

Key specifications
ADT226 electrical accuracy0.015 % of reading + 0.005 % FS (ADT226Ex: 0.02 % of reading + offset)
ADT226 measurement±300 mV, ±30 V, ±30 mA, 0…4000 Ω, 0.01…50000 Hz, thermocouples, RTD; 300 V AC/DC (ADT226 only)
ADT226 generation±15 V, 0…25 mA, resistance 0…4000 Ω, frequency, pulses; 24 V loop power
ADT226 pressureExternal 161 modules, −1…4200 bar, from 0.02 % FS; differential pressure at high static pressure 0.002 % FS
ADT226Ex Ex protectionATEX, IECEx, Ex ia IIC T4 Ga
  • A quote tailored to your application
  • Technical advice on choosing the right model
  • Technical support before and after delivery

Description

Multifunction process calibrators measure, generate and simulate temperature (thermocouple, RTD), pressure and electrical signals, so a single instrument covers most loops in a plant. Both models are supplied with an accredited calibration certificate.

How to choose

  • Additel ADT226 — compact touchscreen calibrator, electrical accuracy 0.015 % of reading + 0.005 % FS, integrated barometer, two ports for pressure modules, voltage measurement up to 300 V AC/DC (True RMS), IP67, USB-C and Bluetooth.
  • Additel ADT226Ex — intrinsically safe ATEX/IECEx version (Ex ia IIC T4 Ga), for oil platforms, refineries, and the chemical and pharmaceutical industries; typical battery life of 35 h.
  • Beamex MC6 — field calibrator and multi-bus communicator for HART, FOUNDATION Fieldbus and Profibus PA, with two simultaneous RTD/TC channels, up to 3 internal pressure modules and a documenting mode for Beamex calibration management software.

Typical use

Calibration of temperature and pressure transmitters, 4–20 mA loops and smart instruments; leak tests and safety valve tests; automated calibrations with compatible calibration furnaces and pressure pumps (MC6).

Available models

  • Additel ADT226 — Multifunction process calibrator with touchscreen, IP67, measurement up to 300 V, integrated barometer.
  • Additel ADT226Ex — Intrinsically safe ATEX/IECEx Ex ia IIC T4 Ga version, typical battery life 35 h.
  • Beamex MC6 — Field calibrator, HART/FF/Profibus PA communicator and documenting calibrator.

Applications

  • Calibration of temperature and pressure transmitters
  • 4–20 mA loop calibration
  • Configuration of HART, FOUNDATION Fieldbus and Profibus PA instruments
  • Leak tests and safety valve tests
  • Potentially explosive atmospheres (ADT226Ex)

Technical specifications

ADT226 electrical accuracy0.015 % of reading + 0.005 % FS (ADT226Ex: 0.02 % of reading + offset)
ADT226 measurement±300 mV, ±30 V, ±30 mA, 0…4000 Ω, 0.01…50000 Hz, thermocouples, RTD; 300 V AC/DC (ADT226 only)
ADT226 generation±15 V, 0…25 mA, resistance 0…4000 Ω, frequency, pulses; 24 V loop power
ADT226 pressureExternal 161 modules, −1…4200 bar, from 0.02 % FS; differential pressure at high static pressure 0.002 % FS
ADT226Ex Ex protectionATEX, IECEx, Ex ia IIC T4 Ga
ADT226 housingIP67, 1 m drop test; 177 × 105 × 52 mm; 0.7 kg (ADT226Ex 0.75 kg)
ADT226 battery lifeTypically 12 h (ADT226), 35 h (ADT226Ex)
Beamex MC6 accuracyPressure from ±(0.005 % FS + 0.0125 % of reading); RTD from ±0.011 °C; current from ±(0.75 µA + 0.0075 % of reading)
Beamex MC6 functionsVoltage ±1 V and −1…60 V DC; current ±100 mA; generation 0…55 mA; frequency 0…50 kHz; RTD and TC on 2 channels; 24 V DC loop supply
Beamex MC6 communicatorHART, FOUNDATION Fieldbus, Profibus PA
Beamex MC6 housingIP65; 200 × 230 × 70 mm; 1.5…2.0 kg; 5.7" 640 × 480 touch display
Beamex MC6 battery life10…16 h
Operating temperatureADT226: −10…50 °C; ADT226Ex: −20…50 °C; MC6: −10…45 °C
InterfacesADT226: USB-C, Bluetooth BLE; MC6: USB, Bluetooth

Documentation

Quote request

Request a quote for this product

Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.

Requested productMultifunction process calibrators — Additel ADT226 and Beamex MC6