Optris CTvideo — pyrometers with video sighting for metals
Infrared pyrometers for metals and ceramics, 250 … 2200 °C, with video camera, cross laser, adjustable focus from 90 mm and 1 ms response.
| Temperature range | 1ML: 485 … 1050 °C; 1MH: 650 … 1800 °C; 1MH1: 800 … 2200 °C; 2ML: 250 … 800 °C; 2MH: 385 … 1600 °C; 2MH1: 490 … 2000 °C |
|---|---|
| Spectral range | 1.0 µm (1M); 1.6 µm (2M); 2.3 µm (3M) |
| Optical resolution (D:S) | 150:1 (1ML, 2ML); 300:1 (1MH, 1MH1, 2MH, 2MH1) |
| Focus | Manual; SF: 200 mm … infinity; CF: 90 … 250 mm |
| Exposure time (90 %) | 1 ms |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
Optris CTvideo pyrometers measure the temperature of metals and ceramics without contact, including where the object is difficult to access. The integrated video camera and the patented cross laser work in parallel and show the measured area under any lighting conditions. The short wavelengths, 1.0 µm or 1.6 µm, reduce errors on surfaces with low or unknown emissivity.
Key benefits
- Manual focus from 90 mm and an optical ratio of up to 300:1.
- 1 ms response time.
- Measuring head separate from the electronics, usable without cooling at ambient temperatures up to 70 °C. The laser switches off automatically at 50 °C.
- 0/4–20 mA, 0–5/10 V, J/K thermocouple and alarm outputs. USB 2.0, extendable over Ethernet up to 100 m.
- Included software for sensor configuration, video alignment, value logging and automatic snapshots (time- or temperature-triggered).
Typical use
- CTvideo 1M: metals at very high temperatures, 485 … 2200 °C.
- CTvideo 2M: metallurgy and metal heating, 250 … 2000 °C.
- CTvideo 3M: metals at lower temperatures.
Applications
- Metallurgy
- Metal heating and heat treatment
- Ceramics
- Hard-to-access processes
Technical specifications
| Temperature range | 1ML: 485 … 1050 °C; 1MH: 650 … 1800 °C; 1MH1: 800 … 2200 °C; 2ML: 250 … 800 °C; 2MH: 385 … 1600 °C; 2MH1: 490 … 2000 °C |
|---|---|
| Spectral range | 1.0 µm (1M); 1.6 µm (2M); 2.3 µm (3M) |
| Optical resolution (D:S) | 150:1 (1ML, 2ML); 300:1 (1MH, 1MH1, 2MH, 2MH1) |
| Focus | Manual; SF: 200 mm … infinity; CF: 90 … 250 mm |
| Exposure time (90 %) | 1 ms |
| Accuracy / repeatability | ±(0.3 % of reading + 2 °C) / ±(0.1 % of reading + 1 °C) |
| Video sighting | Digital (USB 2.0), 640 × 480 px, FOV 3.1° × 2.4° |
| Analog outputs | 0/4–20 mA, 0–5/10 V, J/K thermocouple |
| Alarm output | Open collector, 24 V / 50 mA |
| Digital interface | USB 2.0; Ethernet via optional USB server (up to 100 m) |
| Power supply | 8–36 V DC |
| Ambient temperature | Head: −20 … 70 °C (50 °C with the laser on); electronics: −20 … 85 °C |
| Protection | IP65 (NEMA-4) |
Documentation
Request a quote for this product
Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.
- Send the request (the product is filled in automatically).
- We check the application and the right variant.
- You receive the technical and commercial offer.