Skip to content

IMPAC IS 140 / IGA 140 — fixed pyrometers with focusable optics, Si and InGaAs, 220 … 3500 °C

Digital fixed pyrometers with focusable optics and spot size from 0.35 mm, for metals, ceramics and graphite, 220 … 3500 °C, t90 < 1 ms, RS485 or Profibus/Profinet/Ethernet.

Key specifications
Temperature rangesIS 140: 550 … 3500 °C, depending on version; IGA 140: 220 … 3000 °C, depending on version; adjustable sub-range, minimum 51 °C
Detector / spectral bandIS 140: Si, 0.7–1.1 µm; IGA 140: InGaAs, 1.45–1.8 µm
Measurement uncertaintyBelow 1500 °C: 0.3 % of reading in °C + 1 °C; above 1500 °C: 0.5 % of reading (Tamb = 23 °C)
Repeatability0.1 % of measured value in °C + 1 °C
Response time t90< 1 ms (optionally 500 µs), adjustable up to 10 s
  • A quote tailored to your application
  • Technical advice on choosing the right model
  • Technical support before and after delivery

Description

The IMPAC IS 140 / IGA 140 series measures the temperature of metals, ceramics and graphite without contact, between 220 and 3500 °C. The pyrometers have focusable optics, so the measuring point can be set to the actual working distance, with a minimum spot of 0.35 mm. The integrated digital display and precision mounting rail make installation and alignment easier.

IS 140 or IGA 140? The IS 140 has a silicon (Si) detector with a 0.7–1.1 µm band and is intended for high temperatures: standard versions from 550 °C up to 3300 °C (3500 °C in special versions). The IGA 140 has an InGaAs detector with a 1.45–1.8 µm band and starts measuring lower: versions from 220 or 300 °C up to 3000 °C. Both operate at short wavelengths, suited to metals.

Key benefits

  • Very fast response: t90 below 1 ms, optionally 500 µs; adjustable up to 10 s.
  • Three focusable optics (130 … 200 mm, 190 … 420 mm, 340 … 4000 mm), interchangeable without recalibration, adjustable with one hand.
  • Selectable sighting: parallax-free through-the-lens viewfinder or sighting laser, usable during measurement.
  • Industrial communication: switchable RS232/RS485 or, on the PB/PN/ET versions, Profibus-DP, Profinet or Ethernet; 0/4–20 mA output with a test current output.
  • Dedicated versions: a forging version and versions with special wavelengths (0.676 µm and 0.55 µm).

Typical use

Preheating, annealing, tempering, hardening, normalizing, welding, forging, rolling, sintering, melting, soldering and brazing.

Applications

  • Preheating
  • Annealing
  • Tempering and hardening
  • Normalizing
  • Welding
  • Forging
  • Rolling
  • Sintering
  • Melting
  • Soldering and brazing
  • Ceramics and graphite

Technical specifications

Temperature rangesIS 140: 550 … 3500 °C, depending on version; IGA 140: 220 … 3000 °C, depending on version; adjustable sub-range, minimum 51 °C
Detector / spectral bandIS 140: Si, 0.7–1.1 µm; IGA 140: InGaAs, 1.45–1.8 µm
Measurement uncertaintyBelow 1500 °C: 0.3 % of reading in °C + 1 °C; above 1500 °C: 0.5 % of reading (Tamb = 23 °C)
Repeatability0.1 % of measured value in °C + 1 °C
Response time t90< 1 ms (optionally 500 µs), adjustable up to 10 s
Emissivity10 … 100 %, in 0.1 % steps
Optics3 focusable optics: 130 … 200 mm, 190 … 420 mm, 340 … 4000 mm; minimum spot 0.35 mm
SightingThrough-the-lens viewfinder or sighting laser (< 1 mW, 630 … 680 nm, class II)
Analog output0–20 mA or 4–20 mA, linear, switchable; max. load 500 Ω; test current output
Digital interfaceRS232 or addressable RS485, up to 115 kBd; optional Profibus-DP, Profinet or Ethernet
Power supply24 V AC/DC (14 … 30 V), max. 2 VA
Protection ratingIP65 (DIN 40050)
Ambient temperature0 … 70 °C at housing (storage −20 … 80 °C)
WeightApprox. 550 g

Documentation

Quote request

Request a quote for this product

Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.

Requested productIMPAC IS 140 / IGA 140 — fixed pyrometers with focusable optics, Si and InGaAs, 220 … 3500 °C
  1. Send the request (the product is filled in automatically).
  2. We check the application and the right variant.
  3. You receive the technical and commercial offer.

    Drawing, requirements sheet, photo of the measuring point — PDF, Word, Excel, images or ZIP, max. 10 MB.
    Powered by TSync