IMPAC IS 140 / IGA 140 — fixed pyrometers with focusable optics, Si and InGaAs, 220 … 3500 °C
Digital fixed pyrometers with focusable optics and spot size from 0.35 mm, for metals, ceramics and graphite, 220 … 3500 °C, t90 < 1 ms, RS485 or Profibus/Profinet/Ethernet.
| Temperature ranges | IS 140: 550 … 3500 °C, depending on version; IGA 140: 220 … 3000 °C, depending on version; adjustable sub-range, minimum 51 °C |
|---|---|
| Detector / spectral band | IS 140: Si, 0.7–1.1 µm; IGA 140: InGaAs, 1.45–1.8 µm |
| Measurement uncertainty | Below 1500 °C: 0.3 % of reading in °C + 1 °C; above 1500 °C: 0.5 % of reading (Tamb = 23 °C) |
| Repeatability | 0.1 % of measured value in °C + 1 °C |
| Response time t90 | < 1 ms (optionally 500 µs), adjustable up to 10 s |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
The IMPAC IS 140 / IGA 140 series measures the temperature of metals, ceramics and graphite without contact, between 220 and 3500 °C. The pyrometers have focusable optics, so the measuring point can be set to the actual working distance, with a minimum spot of 0.35 mm. The integrated digital display and precision mounting rail make installation and alignment easier.
IS 140 or IGA 140? The IS 140 has a silicon (Si) detector with a 0.7–1.1 µm band and is intended for high temperatures: standard versions from 550 °C up to 3300 °C (3500 °C in special versions). The IGA 140 has an InGaAs detector with a 1.45–1.8 µm band and starts measuring lower: versions from 220 or 300 °C up to 3000 °C. Both operate at short wavelengths, suited to metals.
Key benefits
- Very fast response: t90 below 1 ms, optionally 500 µs; adjustable up to 10 s.
- Three focusable optics (130 … 200 mm, 190 … 420 mm, 340 … 4000 mm), interchangeable without recalibration, adjustable with one hand.
- Selectable sighting: parallax-free through-the-lens viewfinder or sighting laser, usable during measurement.
- Industrial communication: switchable RS232/RS485 or, on the PB/PN/ET versions, Profibus-DP, Profinet or Ethernet; 0/4–20 mA output with a test current output.
- Dedicated versions: a forging version and versions with special wavelengths (0.676 µm and 0.55 µm).
Typical use
Preheating, annealing, tempering, hardening, normalizing, welding, forging, rolling, sintering, melting, soldering and brazing.
Applications
- Preheating
- Annealing
- Tempering and hardening
- Normalizing
- Welding
- Forging
- Rolling
- Sintering
- Melting
- Soldering and brazing
- Ceramics and graphite
Technical specifications
| Temperature ranges | IS 140: 550 … 3500 °C, depending on version; IGA 140: 220 … 3000 °C, depending on version; adjustable sub-range, minimum 51 °C |
|---|---|
| Detector / spectral band | IS 140: Si, 0.7–1.1 µm; IGA 140: InGaAs, 1.45–1.8 µm |
| Measurement uncertainty | Below 1500 °C: 0.3 % of reading in °C + 1 °C; above 1500 °C: 0.5 % of reading (Tamb = 23 °C) |
| Repeatability | 0.1 % of measured value in °C + 1 °C |
| Response time t90 | < 1 ms (optionally 500 µs), adjustable up to 10 s |
| Emissivity | 10 … 100 %, in 0.1 % steps |
| Optics | 3 focusable optics: 130 … 200 mm, 190 … 420 mm, 340 … 4000 mm; minimum spot 0.35 mm |
| Sighting | Through-the-lens viewfinder or sighting laser (< 1 mW, 630 … 680 nm, class II) |
| Analog output | 0–20 mA or 4–20 mA, linear, switchable; max. load 500 Ω; test current output |
| Digital interface | RS232 or addressable RS485, up to 115 kBd; optional Profibus-DP, Profinet or Ethernet |
| Power supply | 24 V AC/DC (14 … 30 V), max. 2 VA |
| Protection rating | IP65 (DIN 40050) |
| Ambient temperature | 0 … 70 °C at housing (storage −20 … 80 °C) |
| Weight | Approx. 550 g |
Documentation
Request a quote for this product
Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.
- Send the request (the product is filled in automatically).
- We check the application and the right variant.