Fuji Electric Time Delta-C — fixed ultrasonic flowmeter with clamp-on sensors
Fuji Electric Time Delta-C fixed ultrasonic flowmeter with sensors mounted on the outside of the pipe, Ø 13 … 6000 mm, 1.0 % of reading accuracy, 0.2 s response, 4–20 mA output.
| Measuring principle | Ultrasonic, transit time, clamp-on sensors |
|---|---|
| Pipe diameter | Ø 13 … 6000 mm, depending on detector type |
| Flow velocity | −32 … +32 m/s, bidirectional |
| Accuracy | 1.0 % of reading |
| Response time | ≤ 0.2 s (fast response mode) |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
The Fuji Electric Time Delta-C measures liquid flow in closed pipes without cutting into the pipe: two sensors are clamped on the outside, and the converter calculates flow from the difference in ultrasonic transit time with and against the flow. With no contact with the fluid, there is no pressure loss, no leakage risk and no sensor corrosion. It suits metal or plastic pipes with diameters of 13 … 6000 mm.
Key benefits
- Accuracy of 1.0 % of reading, through dynamic flow profile correction (Reynolds number and K factor calculated at each velocity).
- The Advanced ABM (anti-bubble measuring) method keeps the measurement stable in liquids with bubbles, suspensions, sludge or wastewater.
- Bidirectional measurement, −32 … +32 m/s, with 0.2 s response time in fast mode.
- Compact converter of about 1.5 kg, with backlit display, sealed keypad and configuration from the front panel or via PC (PC Loader software included).
- Sensors for fluid temperatures of −40 … +200 °C, including a rail-extendable detector for Ø 50 … 1200 mm.
Typical use
Retrofit installation on existing pipes where stopping the process or cutting the pipe is not acceptable. Included functions: totalizer, two automatic ranges, alarm contacts, flow and totalizer switch, low-flow cutoff.
Available models
- Fuji Electric Time Delta-C (FSV) — Clamp-on ultrasonic flowmeter, single channel, Ø 13 … 6000 mm.
- Fuji Electric Time Delta-C Advanced (FSVL) — Version for 2 pipes simultaneously or one pipe with 2 measuring paths.
- Fuji Electric S-Flow (FSZ) — Very compact integral ultrasonic flowmeter for thin pipes of 8 … 32 mm.
- Fuji Electric M-Flow PW (FLR) — Compact, economical fixed transmitter for pipes of 25 … 1200 mm.
Applications
- Water and wastewater
- Liquids with bubbles or suspensions
- Industrial processes
- Installation on existing pipes without stopping the process
Technical specifications
| Measuring principle | Ultrasonic, transit time, clamp-on sensors |
|---|---|
| Pipe diameter | Ø 13 … 6000 mm, depending on detector type |
| Flow velocity | −32 … +32 m/s, bidirectional |
| Accuracy | 1.0 % of reading |
| Response time | ≤ 0.2 s (fast response mode) |
| Fluid temperature | −40 … +200 °C, depending on detector (FSSC, FSSA, FSSD, FSSH, FSSE) |
| Analog output | 1 × 4–20 mA, isolated, max. load 600 Ω |
| Digital outputs | 2 isolated transistor contacts, max. 100 pulses/s |
| Communication | RS485 (Modbus, optional) |
| Power supply | 100 … 240 V AC or 20 … 30 V DC |
| Detector ingress protection | IP52 … IP67, depending on type; submersible versions available |
| Converter weight | approx. 1.5 kg; wall or pipe mounting |