Skip to content

Fuji Electric Time Delta-C — fixed ultrasonic flowmeter with clamp-on sensors

Fuji Electric Time Delta-C fixed ultrasonic flowmeter with sensors mounted on the outside of the pipe, Ø 13 … 6000 mm, 1.0 % of reading accuracy, 0.2 s response, 4–20 mA output.

Key specifications
Measuring principleUltrasonic, transit time, clamp-on sensors
Pipe diameterØ 13 … 6000 mm, depending on detector type
Flow velocity−32 … +32 m/s, bidirectional
Accuracy1.0 % of reading
Response time≤ 0.2 s (fast response mode)
  • A quote tailored to your application
  • Technical advice on choosing the right model
  • Technical support before and after delivery

Description

The Fuji Electric Time Delta-C measures liquid flow in closed pipes without cutting into the pipe: two sensors are clamped on the outside, and the converter calculates flow from the difference in ultrasonic transit time with and against the flow. With no contact with the fluid, there is no pressure loss, no leakage risk and no sensor corrosion. It suits metal or plastic pipes with diameters of 13 … 6000 mm.

Key benefits

  • Accuracy of 1.0 % of reading, through dynamic flow profile correction (Reynolds number and K factor calculated at each velocity).
  • The Advanced ABM (anti-bubble measuring) method keeps the measurement stable in liquids with bubbles, suspensions, sludge or wastewater.
  • Bidirectional measurement, −32 … +32 m/s, with 0.2 s response time in fast mode.
  • Compact converter of about 1.5 kg, with backlit display, sealed keypad and configuration from the front panel or via PC (PC Loader software included).
  • Sensors for fluid temperatures of −40 … +200 °C, including a rail-extendable detector for Ø 50 … 1200 mm.

Typical use

Retrofit installation on existing pipes where stopping the process or cutting the pipe is not acceptable. Included functions: totalizer, two automatic ranges, alarm contacts, flow and totalizer switch, low-flow cutoff.

Available models

  • Fuji Electric Time Delta-C (FSV) — Clamp-on ultrasonic flowmeter, single channel, Ø 13 … 6000 mm.
  • Fuji Electric Time Delta-C Advanced (FSVL) — Version for 2 pipes simultaneously or one pipe with 2 measuring paths.
  • Fuji Electric S-Flow (FSZ) — Very compact integral ultrasonic flowmeter for thin pipes of 8 … 32 mm.
  • Fuji Electric M-Flow PW (FLR) — Compact, economical fixed transmitter for pipes of 25 … 1200 mm.

Applications

  • Water and wastewater
  • Liquids with bubbles or suspensions
  • Industrial processes
  • Installation on existing pipes without stopping the process

Technical specifications

Measuring principleUltrasonic, transit time, clamp-on sensors
Pipe diameterØ 13 … 6000 mm, depending on detector type
Flow velocity−32 … +32 m/s, bidirectional
Accuracy1.0 % of reading
Response time≤ 0.2 s (fast response mode)
Fluid temperature−40 … +200 °C, depending on detector (FSSC, FSSA, FSSD, FSSH, FSSE)
Analog output1 × 4–20 mA, isolated, max. load 600 Ω
Digital outputs2 isolated transistor contacts, max. 100 pulses/s
CommunicationRS485 (Modbus, optional)
Power supply100 … 240 V AC or 20 … 30 V DC
Detector ingress protectionIP52 … IP67, depending on type; submersible versions available
Converter weightapprox. 1.5 kg; wall or pipe mounting

Documentation

Quote request

Request a quote for this product

Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.

Requested productFuji Electric Time Delta-C — fixed ultrasonic flowmeter with clamp-on sensors
  1. Send the request (the product is filled in automatically).
  2. We check the application and the right variant.
  3. You receive the technical and commercial offer.

    Drawing, requirements sheet, photo of the measuring point — PDF, Word, Excel, images or ZIP, max. 10 MB.
    Powered by TSync