Fuji Electric Portaflow-C (FSC) — portable clamp-on ultrasonic flowmeter
Fuji Electric FSC portable ultrasonic flowmeter with clamp-on sensors: pipes Ø 13 … 6000 mm, ±1.0 % of reading, SD card logging, thermal energy calculation, 12 h battery life.
| Measuring principle | Ultrasonic, transit-time difference, 1 path |
|---|---|
| Pipe inner diameter | Ø 13 … 6000 mm, depending on detector |
| Fluid temperature | −40 … +200 °C, depending on detector |
| Flow velocity | 0 … ±32 m/s (min. ±0.3 m/s) |
| Accuracy | ±1.0 % of reading, depending on velocity |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
The Fuji Electric Portaflow-C (FSC converter) measures liquid flow from the outside of the pipe, without cutting it, without shutting down the installation and without pressure loss. The clamp-on sensors work on the transit-time difference principle, on pipes with an inner diameter of 13 … 6000 mm. Being battery powered, it is the right instrument for field checks, maintenance, leak detection, energy audits and temporary measurements.
Key benefits
- Accuracy of ±1.0 % of reading (depending on flow velocity), bidirectional measurement up to ±32 m/s.
- Calculation of transferred thermal energy from flow and supply and return temperatures (2 analog inputs 4–20 mA / 1–5 V), for HVAC, heating, cooling and district heating.
- SD card logging and PC transfer via USB; stores configurations for 32 measurement points.
- Backlit color graphic display for instantaneous flow, totalized flow and trends.
- Built-in battery with about 12 hours of operation; IP64 housing, approx. 1 kg.
Typical use
Verification of fixed flowmeters, balances in pumping and water treatment stations, energy audits in HVAC and industrial installations. It can measure water, hot water, distilled water, alcohol, milk, ethanol and other homogeneous liquids through which ultrasound propagates.
Available models
- Fuji Electric Portaflow-C (FSC + FSD detectors) — Portable ultrasonic flowmeter, with optional printer and velocity profile (Pulse Doppler).
Applications
- Field checks and maintenance
- Leak detection
- Energy audits
- HVAC, heating and cooling installations
- Water supply and treatment
- Pumping stations
Technical specifications
| Measuring principle | Ultrasonic, transit-time difference, 1 path |
|---|---|
| Pipe inner diameter | Ø 13 … 6000 mm, depending on detector |
| Fluid temperature | −40 … +200 °C, depending on detector |
| Flow velocity | 0 … ±32 m/s (min. ±0.3 m/s) |
| Accuracy | ±1.0 % of reading, depending on velocity |
| Response time | 1 s |
| Analog output | 1 × 4–20 mA DC |
| Analog inputs | 2 × 4–20 mA DC / 1–5 V DC |
| Memory and interface | SD card; USB, max. distance 3 m; 32 measurement points stored |
| Display | Backlit color graphic LCD |
| Power supply | Built-in battery; approx. 12 h continuous operation |
| Ingress protection | IP64 |
| Dimensions and weight | 210 × 120 × 65 mm (without printer); approx. 1 kg |
Documentation
Request a quote for this product
Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.
- Send the request (the product is filled in automatically).
- We check the application and the right variant.
- You receive the technical and commercial offer.