Fuji Electric FSJ — clamp-on ultrasonic flowmeter for saturated steam
Fuji Electric FSJ/FSX clamp-on ultrasonic flowmeter for saturated steam, pipes 50 … 100 mm, 0.1 … 0.9 MPa, measurement down to zero flow, mass flow conversion, 4–20 mA and RS-485.
| Fluid | Saturated steam, without moisture (100 % quality) |
|---|---|
| Measuring principle | Ultrasonic, transit-time difference, clamp-on |
| Pipe diameters | 50, 65, 80, 100 mm (50A … 100A) |
| Pipe material | Carbon steel, stainless steel |
| Steam pressure | 0.1 … 0.9 MPa gauge (0.2 … 0.9 MPa for 65A and above) |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
The Fuji Electric FSJ (converter) together with the FSX detector measures saturated steam flow from the outside of the pipe. Installation requires no pipe cutting or flanges and is done without shutting down the line, so there is no risk of steam leaks. High-sensitivity ultrasonic sensors and noise reduction technology allow steam measurement at 0.1 … 0.9 MPa (gauge), where conventional clamp-on flowmeters did not work.
Key benefits
- No pipe work and no pressure loss.
- Measures down to zero flow, which other types of steam flowmeters cannot do.
- No moving parts: low maintenance cost and no damage from water hammer.
- Mass flow conversion, with density corrected from pressure and temperature (Pt100) inputs.
- 0.2 s response; RS-485 (Modbus) communication with self-diagnostics and remote diagnostics functions.
Typical use
Monitoring steam consumption on process lines and points of use, boilers and distribution networks, energy management and integration into automation or energy management systems.
Available models
- Fuji Electric FSJ + FSX — FSJ flow converter with FSX clamp-on detector and preamplifier, for saturated steam.
Applications
- Steam consumption monitoring
- Energy management
- Boilers and steam distribution networks
- Metering on process lines
- Energy management systems
Technical specifications
| Fluid | Saturated steam, without moisture (100 % quality) |
|---|---|
| Measuring principle | Ultrasonic, transit-time difference, clamp-on |
| Pipe diameters | 50, 65, 80, 100 mm (50A … 100A) |
| Pipe material | Carbon steel, stainless steel |
| Steam pressure | 0.1 … 0.9 MPa gauge (0.2 … 0.9 MPa for 65A and above) |
| Flow velocity | 0 … ±50 m/s |
| Accuracy (50A) | ±3.0 % (10 … 30 m/s); ±5.0 % (30 … 50 m/s); ±0.3 m/s (0 … 10 m/s) |
| Accuracy (65A … 100A) | ±4.0 % (10 … 30 m/s); ±5.0 % (30 … 50 m/s); ±0.4 m/s (0 … 10 m/s) |
| Response time | 0.2 s |
| Outputs and communication | 4–20 mA, pulse; RS-485 (Modbus) |
| Power supply | 100 … 240 V AC, 50/60 Hz, max. 20 VA |
| Ingress protection | IP67 (with connectors fitted) |
| Ambient temperature | −20 … +60 °C in operation |
Documentation
Request a quote for this product
Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.
- Send the request (the product is filled in automatically).
- We check the application and the right variant.
- You receive the technical and commercial offer.