Skip to content

BoilerSpection — through-flame thermal imaging for boilers and furnaces (500–1600 °C)

3.9 µm infrared cameras that see through flame in boilers, furnaces and incinerators: slag and ash deposits, at 500–1600 °C, fixed or mobile.

Key specifications
Measuring range500 … 1600 °C
Wavelength3.9 µm, narrow band
DetectorUncooled VOx microbolometer, 320 × 240 pixels
Field of view (H × V)50° × 38°, manual focus
OpticsStainless steel, 42 mm diameter, sapphire window tip with air purge
  • A quote tailored to your application
  • Technical advice on choosing the right model
  • Technical support before and after delivery

Description

Without an image from inside the furnace, boiler cleaning is done on a schedule, not according to the actual condition of the tubes. The result: unnecessary cleaning, reduced heat transfer and large deposits (clinkers) that end up damaging the tubes. BoilerSpection systems use an infrared detector with a narrow 3.9 µm filter, which sees through flame. The operator receives real-time images and temperatures across the entire image, in the 500–1600 °C range.

With this data, operators can direct cleaning where it is needed, adjust fuel and air flow and track deposit uniformity when the fuel changes. The boiler thus recovers lost capacity, and efficiency and emissions improve.

How to choose the version

  • Continuous monitoring: BoilerSpection SD – fixed cameras on the furnace wall, with automatic retraction on loss of air or power. Up to 24 cameras on a single controller, LumaSpec RT software, outputs to DCS/PLC, OPC and Modbus.
  • Spot inspections or semi-permanent installation: BoilerSpection MB – mobile camera with 18″, 24″ or 36″ borescope optics, supplied with an industrial laptop, recording and analysis software and an air kit. It is compatible with the SD system.

The SD system can be installed with the boiler in operation or during shutdown. It requires access ports with 50 mm clearance and instrument-quality compressed air.

Available models

  • BoilerSpection SD — Fixed system for continuous through-flame monitoring, with automatic retraction and DCS integration.
  • BoilerSpection MB — Mobile camera for inspecting boiler tubes and furnace walls, with 18″, 24″ or 36″ borescope optics.

Applications

  • Power boilers
  • Industrial combustion furnaces
  • Incinerators
  • Boiler tube cleaning optimization
  • Combustion control

Technical specifications

Measuring range500 … 1600 °C
Wavelength3.9 µm, narrow band
DetectorUncooled VOx microbolometer, 320 × 240 pixels
Field of view (H × V)50° × 38°, manual focus
OpticsStainless steel, 42 mm diameter, sapphire window tip with air purge
Housing (SD)IP66, with integrated vortex cooling
Ambient temperatureUp to 60 °C
Network (SD)Up to 24 cameras per controller; 100Base-T Ethernet; multimode fiber to the control room
Air supply (SD)20–30 scfm at min. 80 psi per camera
Electrical supply (SD)110–240 V AC, two 15 A lines for six cameras
Mounting (SD)Welded or bolted plates; 50 mm opening in the membrane wall
Furnace pressureNegative, balanced or positive
Frame rate (MB)30 Hz / 9 Hz; NTSC/PAL video output (BNC)
Camera weight13.5 kg (SD); under 13.5 kg (MB)

Documentation

Quote request

Request a quote for this product

Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.

Requested productBoilerSpection — through-flame thermal imaging for boilers and furnaces (500–1600 °C)
  1. Send the request (the product is filled in automatically).
  2. We check the application and the right variant.
  3. You receive the technical and commercial offer.

    Drawing, requirements sheet, photo of the measuring point — PDF, Word, Excel, images or ZIP, max. 10 MB.