Ascon Tecnologic ZO2-4 zirconia oxygen probes
ZO2-4 zirconia probes for direct, continuous measurement of residual oxygen in flue gas, with 4–20 mA or 0–10 V output.
| Measuring principle | Direct, continuous measurement of O₂ in wet flue gas |
|---|---|
| Sensor | Heated zirconia (ZrO₂) |
| Measuring range | 0.3 … 25 % O₂ |
| Accuracy | ±0.5 % of full scale (in the 0.5 … 20.9 % O₂ range) |
| Output scale | 0 … 20.96 % or 0 … 25 % O₂, selectable via DIP |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
Ascon Tecnologic ZO2-4 probes measure the residual oxygen percentage in wet flue gas directly and continuously, using a heated zirconia sensor. The signal is used for combustion monitoring or burner control, so the boiler operates in the optimum air–fuel ratio range.
All versions have control electronics with a non-isolated active 4–20 mA or 0–10 V output, selectable via DIP switches, a dual-scale range and calibration in ambient air via trimmer, without calibration gas cylinders. The probe is used on natural gas plants. For other fuels, always with low sulfur content, the application is assessed together with our technical department.
How to choose
- Integrated electronics (ZO2-4I): compact solution, for standard conditions.
- Separate electronics (ZO2-4E): for high ambient temperatures or stack vibration; supplied with a 3 m cable.
- M or B tube: in-situ for natural gas or methane (M) or for biomass, with purge air connection (B); lengths of 300 or 500 mm.
- C tube (ZO2-4I/E-C060): extractive probe for composting air recirculation ducts, with a condensate drain cylinder and a stilling chamber.
Key benefits
- Response time under 50 ms and accuracy of ±0.5 % of full scale.
- Calibration in ambient air, at 12-month intervals.
- Sensor can be replaced quickly.
- Fault relay for disconnected probe, or faulty probe or heater.
For engines, cogeneration units and boilers, Ascon Tecnologic also offers the ZO2SCHEDA04 board, which handles Bosch LSU 4.9 and 5.2 lambda probes. The board is calibrated in ambient air, without calibration cylinders.
Available models
- ZO2-4I — In-situ probe with electronics integrated in the head, with tube for gas (M) or biomass (B).
- ZO2-4E — In-situ probe with separate electronics and 3 m cable, for high temperatures or vibration.
- ZO2-4I/E-C060 — Extractive probe for composting plants, with integrated or separate electronics.
- ZO2SCHEDA04 — Interface board for Bosch LSU 4.9 and 5.2 lambda probes, with voltage output.
Applications
- Residential boiler plants
- Industrial boiler plants
- Cogeneration plants
- Biomass plants
- District heating networks
- Composting plants
- Solid-fuel or gas-fired boilers
Technical specifications
| Measuring principle | Direct, continuous measurement of O₂ in wet flue gas |
|---|---|
| Sensor | Heated zirconia (ZrO₂) |
| Measuring range | 0.3 … 25 % O₂ |
| Accuracy | ±0.5 % of full scale (in the 0.5 … 20.9 % O₂ range) |
| Output scale | 0 … 20.96 % or 0 … 25 % O₂, selectable via DIP |
| Output | 4–20 mA / 0–10 V, active, non-isolated |
| Response time | < 50 ms |
| Warm-up time | Sensor < 15 s; operating readings after 15 min |
| Flue gas temperature | Max. 500 °C |
| Fault output | SPDT relay, NC/NO |
| Power supply | 24 V DC ±5 %, max. 0.8 A |
| Head protection | IP66 |
| Ambient operating temperature | −20 … +55 °C |
| Process connection | 1" NPT with sliding nipple (in-situ versions); AISI 316 tube |