Ascon Tecnologic OXI, OXM, OXR: O₂ indicator, monitor and controller
48 × 96 mm panel instruments for ZO2 oxygen probes: O₂ indicator, combustion monitor with efficiency calculation and O₂ trim controller.
| Main input | mV directly from the ZO2 probe (0.2 % ±1 digit) or linearized 4–20 mA 0.0 … 20.9 % O₂ |
|---|---|
| Auxiliary analog inputs | OXM: 2 × 4–20 mA (gas and air temperature); OXR: 4–20 mA (boiler load) |
| Logic inputs | OXI: 2; OXM: 3; OXR: 4 |
| Main analog output | 4–20 mA / 0–10 V |
| Alarm outputs | OXI, OXM: 2 NO relays; OXR: 3 NO relays + 1 fault relay; 250 V AC / 5 A |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
The OX series complements ZO2 oxygen probes with panel instruments for display, monitoring and control. All three models take the signal directly in mV from the ZO2 probe, or a 4–20 mA signal linearized over the 0.0 … 20.9 % O₂ range. They come in 1/16 DIN format (48 × 96 mm) with optional RS485 Modbus communication.
How to choose
- OXI, O₂ indicator: displays the oxygen content and retransmits it as 4–20 mA / 0–10 V; it has 2 logic inputs and 2 alarm relays.
- OXM, combustion monitor: with additional inputs for flue gas and air temperature, it calculates efficiency, excess air and CO₂ %. The output can be programmed for any of these values.
- OXR, O₂ trim controller: continuously adjusts the air–fuel ratio through the airflow, according to boiler load. It has up to 2 curves of 4 segments each, a control output, an auxiliary output for O₂ and a fault relay.
With OXR, stack heat losses fall, fuel consumption is reduced and energy is transferred better in the combustion chamber.
Available models
- OXI — O₂ indicator with 4–20 mA / 0–10 V retransmission and 2 relay alarms.
- OXM — Combustion monitor that calculates efficiency, excess air and CO₂ %.
- OXR — O₂ trim controller that corrects airflow according to boiler load.
Applications
- Industrial boiler plants
- Residential boiler plants
- Cogeneration plants
- Biomass plants
Technical specifications
| Main input | mV directly from the ZO2 probe (0.2 % ±1 digit) or linearized 4–20 mA 0.0 … 20.9 % O₂ |
|---|---|
| Auxiliary analog inputs | OXM: 2 × 4–20 mA (gas and air temperature); OXR: 4–20 mA (boiler load) |
| Logic inputs | OXI: 2; OXM: 3; OXR: 4 |
| Main analog output | 4–20 mA / 0–10 V |
| Alarm outputs | OXI, OXM: 2 NO relays; OXR: 3 NO relays + 1 fault relay; 250 V AC / 5 A |
| Serial communication | RS485 Modbus / J-Bus, max. 9600 baud (optional) |
| Power supply | 100 … 240 V AC or 16 … 28 V AC (50/60 Hz) and 20 … 30 V DC |
| Power consumption | Max. 4 VA |
| Format | 48 × 96 mm (1/16 DIN), depth 150 mm; panel cutout 45 × 92 mm |
| Front protection | IP65 with gasket, panel mounted |
| Operating / storage temperature | 0 … 50 °C / −20 … +70 °C |
| Humidity | 35 … 85 % RH, non-condensing |