ADFweb OPC UA – Modbus converters
ADFweb gateways between OPC UA and Modbus RTU (RS232/RS485) or Modbus TCP, in client or server, master or slave versions, on DIN rail.
| Protocols | OPC UA ↔ Modbus RTU (RS232/RS485) or Modbus TCP |
|---|---|
| HD67B09 role | OPC UA client / Modbus slave |
| Data volume | Up to 1500 bytes on read and 1500 on write (HD67B09) |
| Galvanic isolation | Triple (HD67B09) |
| Power supply | 8…24 V AC or 12…35 V DC |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
OPC UA – Modbus converters connect existing Modbus devices to OPC UA applications and servers, and vice versa. They are useful when the upper-level system uses OPC UA while field devices communicate over Modbus RTU or Modbus TCP.
How to choose
- OPC UA client, Modbus slave: HD67B09 (Modbus RTU) and HD67B10 (Modbus TCP); the converter reads an OPC UA server and exposes the data to a Modbus master.
- OPC UA server, Modbus master: HD67B27 / HD67B29; the converter polls the Modbus devices and publishes the data via OPC UA.
- OPC UA server, Modbus slave: HD67B28 / HD67B30.
- Modbus line: RTU over RS232/RS485 or TCP over Ethernet, depending on the model.
The HD67B09 transfers up to 1500 bytes on read and 1500 on write and is configured with the Compositor SW67B09 software.
Available models
- HD67B09 — OPC UA client / Modbus RTU slave (RS232/RS485).
- HD67B10 — OPC UA client / Modbus TCP slave.
- HD67B27 / HD67B29 — OPC UA server / Modbus RTU or Modbus TCP master.
- HD67B28 / HD67B30 — OPC UA server / Modbus RTU or Modbus TCP slave.
Applications
- Integration of Modbus devices into OPC UA networks
- Industrial automation
Technical specifications
| Protocols | OPC UA ↔ Modbus RTU (RS232/RS485) or Modbus TCP |
|---|---|
| HD67B09 role | OPC UA client / Modbus slave |
| Data volume | Up to 1500 bytes on read and 1500 on write (HD67B09) |
| Galvanic isolation | Triple (HD67B09) |
| Power supply | 8…24 V AC or 12…35 V DC |
| Mounting | 35 mm DIN rail |
| Operating temperature | −40…+85 °C |
| Power consumption | 4 W/VA at 24 V DC (HD67B09) |
| Configuration | Compositor SW67B09 software |
Documentation
Request a quote for this product
Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.
- Send the request (the product is filled in automatically).
- We check the application and the right variant.
- You receive the technical and commercial offer.