Skip to content

ADFweb OPC UA – Modbus converters

Manufacturer: ADFwebOPC UA – Modbus

ADFweb gateways between OPC UA and Modbus RTU (RS232/RS485) or Modbus TCP, in client or server, master or slave versions, on DIN rail.

Key specifications
ProtocolsOPC UA ↔ Modbus RTU (RS232/RS485) or Modbus TCP
HD67B09 roleOPC UA client / Modbus slave
Data volumeUp to 1500 bytes on read and 1500 on write (HD67B09)
Galvanic isolationTriple (HD67B09)
Power supply8…24 V AC or 12…35 V DC
  • A quote tailored to your application
  • Technical advice on choosing the right model
  • Technical support before and after delivery

Description

OPC UA – Modbus converters connect existing Modbus devices to OPC UA applications and servers, and vice versa. They are useful when the upper-level system uses OPC UA while field devices communicate over Modbus RTU or Modbus TCP.

How to choose

  • OPC UA client, Modbus slave: HD67B09 (Modbus RTU) and HD67B10 (Modbus TCP); the converter reads an OPC UA server and exposes the data to a Modbus master.
  • OPC UA server, Modbus master: HD67B27 / HD67B29; the converter polls the Modbus devices and publishes the data via OPC UA.
  • OPC UA server, Modbus slave: HD67B28 / HD67B30.
  • Modbus line: RTU over RS232/RS485 or TCP over Ethernet, depending on the model.

The HD67B09 transfers up to 1500 bytes on read and 1500 on write and is configured with the Compositor SW67B09 software.

Available models

  • HD67B09 — OPC UA client / Modbus RTU slave (RS232/RS485).
  • HD67B10 — OPC UA client / Modbus TCP slave.
  • HD67B27 / HD67B29 — OPC UA server / Modbus RTU or Modbus TCP master.
  • HD67B28 / HD67B30 — OPC UA server / Modbus RTU or Modbus TCP slave.

Applications

  • Integration of Modbus devices into OPC UA networks
  • Industrial automation

Technical specifications

ProtocolsOPC UA ↔ Modbus RTU (RS232/RS485) or Modbus TCP
HD67B09 roleOPC UA client / Modbus slave
Data volumeUp to 1500 bytes on read and 1500 on write (HD67B09)
Galvanic isolationTriple (HD67B09)
Power supply8…24 V AC or 12…35 V DC
Mounting35 mm DIN rail
Operating temperature−40…+85 °C
Power consumption4 W/VA at 24 V DC (HD67B09)
ConfigurationCompositor SW67B09 software

Documentation

Quote request

Request a quote for this product

Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.

Requested productADFweb OPC UA – Modbus converters
  1. Send the request (the product is filled in automatically).
  2. We check the application and the right variant.
  3. You receive the technical and commercial offer.

    Drawing, requirements sheet, photo of the measuring point — PDF, Word, Excel, images or ZIP, max. 10 MB.