ADFweb HD67911-A1 HART – PROFIBUS converter
ADFweb HD67911-A1 gateway: up to 15 HART instruments integrated into a PROFIBUS network, primary or secondary HART master, triple isolation, DIN rail.
| Protocols | PROFIBUS slave ↔ HART master |
|---|---|
| HART instruments | Up to 15 + 1 secondary master |
| HART mode | FSK; primary or secondary master |
| HART loop power | Current loop and 24 V DC for instruments, enabled from DIP switch |
| PROFIBUS connector | 9-pin D-sub; speed detected automatically |
- A quote tailored to your application
- Technical advice on choosing the right model
- Technical support before and after delivery
Description
The HD67911-A1 integrates HART sensors and transmitters into a PROFIBUS network, for example to a Siemens PLC or a SCADA system. On the PROFIBUS side it works as a slave, and on the HART loop as a master, reading and writing instrument variables.
Key benefits
- Up to 15 HART instruments plus a secondary master on the same loop.
- Can operate as a primary or secondary HART master; HART FSK communication superimposed on 4–20 mA.
- Can supply the current loop for HART and a low-power 24 V DC supply for instruments, enabled from a DIP switch.
- Triple isolation between PROFIBUS, HART and power supply.
- PROFIBUS speed is detected automatically; PROFIBUS connection on a 9-pin D-sub.
Typical use
Bringing into the PLC the additional HART information beyond the 4–20 mA process variable (variables read and written through the gateway). Configuration is done with the Compositor SW67912 software, via the converter’s Ethernet port.
Applications
- Integration of HART sensors and transmitters into PROFIBUS networks
- Siemens PLCs
- SCADA systems
Technical specifications
| Protocols | PROFIBUS slave ↔ HART master |
|---|---|
| HART instruments | Up to 15 + 1 secondary master |
| HART mode | FSK; primary or secondary master |
| HART loop power | Current loop and 24 V DC for instruments, enabled from DIP switch |
| PROFIBUS connector | 9-pin D-sub; speed detected automatically |
| Configuration port | Ethernet |
| Galvanic isolation | Triple: PROFIBUS – power supply, PROFIBUS – HART, HART – power supply |
| Power supply | 8…24 V AC or 12…35 V DC |
| Mounting | 35 mm DIN rail |
| Operating temperature | −40…+85 °C |
| Power consumption | 3.5 W/VA at 24 V DC |
| Configuration | Compositor SW67912 software |
Documentation
Request a quote for this product
Fill in the form; a TempSystem engineer will reply with a quote and, if needed, with questions about your application.
- Send the request (the product is filled in automatically).
- We check the application and the right variant.
- You receive the technical and commercial offer.